Description
Paranoia allows you to lock the module from displaying information, as
well as enables the protection of the filesystem and module settings.
Each bit corresponds corresponds to a different lock level, while
sending a zero will unlock your display as the following tables explains:
Bit Data Lock Level Description
0-2 Reserved Should be left 0
3 Communication
Speed Lock
When this bit is set (1) the
Baud Rate and I
2
C Slave
address are locked
4 Setting Lock When this bit is set (1)
the display settings such
as backlight, contrast and
GPO settings are locked.
(Internal EEPROM)
5 Filesystem Lock When this bit is set (1)
the external EEPROM is
locked, this has the same
effect as the File System
Jumper
6 Command Lock When this bit is set (1) all
commands but commands
202/203 are locked. (cmd
lock)
7 Display Lock When this bit is set (1) the
module is locked from dis-
playing any new informa-
tion. (text lock)
NOTES
• Sending a new data lock level will override the previous data lock level.
• Data lock levels may be combined.
Remembered Always
Default 0
Examples
Hex Dec Binary Description
0x00 0 0 Unlock
0x50 80 01010000 Setting and Command Lock