8.8 Miscellaneous Commands
NOTE The letter “R” in the default column indicates that this state can be saved to non-
volatile memory with the “Remember” command.
Table 33: Miscellaneous Commands
Command Syntax Default Notes
Remember FE 93 [0|1]
254 147
off Turns the “re-
member” func-
tion on [1] or off
[0].
Clear display FE 58
254 88
254 “X”
n/a Clears screen of
text and graphics,
places text cursor
at top left.
Set brightness FE 59 [brightness] 254
89 [brightness] 254 ’Y’
[brightness]
0x00
R
Sets display
brightness.
Brightness is a
value between
0x00 and 0xFF.
Where 0x00 is
“dim” and 0xFF
is “bright”.
Set brightness and save FE 91 [brightness]
245 145 [brightness]
0xFF
R
Sets display
brightness and
saves on sub-
suquent power
ups. Brightness is
a value between
0x00 and 0xFF.
Where 0x00 is
"dim" and 0xFF
is "bright".
Display on FE 42 [minutes]
254 66 [minutes]
254 “B” [minutes]
on
R
Display will stay
on for [minutes].
If [minutes]
= 0 backlight
will stay on
permanently.
Display off FE 46
254 70
254 “F”
on
R
Turns the display
off.
Matrix Orbital PK202-24-USB 38
Comentarios a estos manuales