Matrix-orbital GLK12232-25-SM Manual de usuario Pagina 12

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 70
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 11
Power/Connector Regular GLK12232-25-SM input -V option input
Vcc +5V only 9-15V
+5V +5V only N/C
+12V N/C +12V
NOTE +12V is nominal for the -V but supply of 9-15V is acceptable
Figure 11: Power and Data Configuration
To power up and communicate with a GLK12232-25-SM (standard or wide voltage options), the users
have two options for connections:
power and data connections using the Power/Data Connector of the GLK12232-25-SM (supply Vcc
with the proper voltage)
power connections using the Floppy Power connector and data (RX/TX) and ground using the Power/Data
connector
NOTES
A common ground should be used at all times
Each module ordered has specific voltages and cannot be interchanged
Matrix Orbital GLK12232-25-SM 7
Vista de pagina 11
1 2 ... 7 8 9 10 11 12 13 14 15 16 17 ... 69 70

Comentarios a estos manuales

Sin comentarios