Syntax
Hexadecimal 0xFE 0x57 [Num]
Decimal 254 87 [Num]
ASCII 254 “W” [Num]
Parameters
Parameter Length Description
Num 1 GPO number.
Description This command turns ON general purpose output [num]. The standard
GPO’s on the output 20mA of current at 5V.
NOTE ON means the output is pulled LOW.
Remembered Yes
9.4 Set Startup GPO state
Syntax
Hexadecimal 0xFE 0xC3 [Num] [state]
Decimal 254 195 [Num] [state]
Parameters
Parameter Length Description
Num 1 GPO number.
state 1 Startup state (0: Off, 1: On)
Description This command will set the startup state for the GPO on the next power
up. A value of one will cause the GPO to be off on the next startup
while a value of one will cause the GPO to be on.
NOTE This command does not affect the current state of the GPO.
Remembered Always
10 Display Functions
10.1 Introduction
The employs software controlled display settings, which allow for control over, clearing the screen,
changing the brightness and contrast or setting timers for turning it on or off. The combination of these
allow you complete software control over your display’s appearance.
10.2 Clear Screen