Matrix-orbital GLK19264-7T-1U Manual de usuario Pagina 30

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 71
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 29
Parameters
Parameter Length Description
col 1 Column
row 1 Row
Description This command sets the text insertion point to the [col] and [row]
specified. The insertion point is positioned using the base size of the
current font (this command does not position the insertion point at a
specific pixel). The column used is determined by multiplying the width
of the widest character in the font by the [column]. The row used is
determined by multiplying the height of the font by [row + Metrics: line
spacing].
Remembered No
6.4 Setting the Cursor Coordinate
Syntax
Hexadecimal 0xFE 0x79 [x] [y]
Decimal 254 121 [x] [y]
ASCII 254 “y” [x] [y]
Parameters
Parameter Length Description
x 1 The horizontal position in pixels.
y 1 The vertical position in pixels.
Description This command positions the insertion point at a specific pixel (X,Y),
which references the top left corner of the font insertion point.
Remembered No
6.5 Auto Scroll On
Syntax
Hexadecimal 0xFE 0x51
Decimal 254 81
ASCII 254 “Q”
Description When auto scrolling is on, it causes the display to shift the entire
display’s contents up to make room for a new line of text when the text
reaches the end of the scroll row defined in the font metrics (the bottom
right character position) see Section 5.4 on page 23.
Remembered Yes
Default On
6.6 Auto Scroll Off
Matrix Orbital GLK19264-7T-1U 25